"Number of entries in this group"
Index
|
Subindex
|
Storage Type
|
Length
|
Access Type
|
Remanent
|
Force Writing
|
Initialize as Invalid
|
Default Value
|
Min Value
|
Max Value
|
0x2200
|
0x0
|
Integer
|
8 Bit
|
Read Only
|
disabled
|
disabled
|
enabled
|
13
|
13
|
13
|
Supported on Platforms:
i.MX 35
|
i.MX 6 A-Series
|
i.MX 6 B-Series
|
ISOBUS
|
Yes
|
Yes
|
Yes
|
No
|
|
"Number of language currently selected. (Set the current language with this variable)"
Enumeration is defined in the Project; directly affects @SettingsLanguageCode
Index
|
Subindex
|
Storage Type
|
Length
|
Access Type
|
Remanent
|
Force Writing
|
Initialize as Invalid
|
Default Value
|
Min Value
|
Max Value
|
0x2200
|
0x1
|
Unsigned
|
8 Bit
|
Read/Write
|
enabled
|
disabled
|
enabled
|
0
|
0
|
127
|
Supported on Platforms:
i.MX 35
|
i.MX 6 A-Series
|
i.MX 6 B-Series
|
ISOBUS
|
Yes
|
Yes
|
Yes
|
No
|
|
"Two byte code for language currently set Default value will match language [0] since default of '@SettingsLanguageEnum' is 0"
similar to ISO 11783-7, A.23.1, codes according to ISO 639 e.g.
"de": german
"en": english
"fr": french
"nl": dutch
As defined in the project.
Index
|
Subindex
|
Storage Type
|
Length
|
Access Type
|
Remanent
|
Force Writing
|
Initialize as Invalid
|
Default Value
|
Min Value
|
Max Value
|
0x2200
|
0x2
|
String
|
2 Byte
|
Read Only
|
disabled
|
disabled
|
enabled
|
de
|
|
|
Supported on Platforms:
i.MX 35
|
i.MX 6 A-Series
|
i.MX 6 B-Series
|
ISOBUS
|
Yes
|
Yes
|
Yes
|
No
|
|
"Symbol used to display numbers with a fractional part"
similar to ISO 11783-7, A.23.2
0: comma
1: point
This affects all numeric fields in the project displaying decimal values with a scaling factor.
Index
|
Subindex
|
Storage Type
|
Length
|
Access Type
|
Remanent
|
Force Writing
|
Initialize as Invalid
|
Default Value
|
Min Value
|
Max Value
|
0x2200
|
0x3
|
Unsigned
|
2 Bit
|
Read/Write
|
enabled
|
disabled
|
enabled
|
1
|
0
|
1
|
Supported on Platforms:
i.MX 35
|
i.MX 6 A-Series
|
i.MX 6 B-Series
|
ISOBUS
|
Yes
|
Yes
|
Yes
|
No
|
|
"date format to be used"
similar to ISO 11783-7, A.23.3
0: ddmmyyyy
1: ddyyyymm
2: mmyyyydd
3: mmddyyyy
4: yyyymmdd
5: yyyyddmm
Index
|
Subindex
|
Storage Type
|
Length
|
Access Type
|
Remanent
|
Force Writing
|
Initialize as Invalid
|
Default Value
|
Min Value
|
Max Value
|
0x2200
|
0x4
|
Unsigned
|
8 Bit
|
Read/Write
|
enabled
|
disabled
|
enabled
|
0
|
0
|
5
|
Supported on Platforms:
i.MX 35
|
i.MX 6 A-Series
|
i.MX 6 B-Series
|
ISOBUS
|
Yes
|
Yes
|
Yes
|
No
|
|
"time format to be used"
similar to ISO 11783-7, A.23.4
0: 24 h
1: 12 h, am/pm
Index
|
Subindex
|
Storage Type
|
Length
|
Access Type
|
Remanent
|
Force Writing
|
Initialize as Invalid
|
Default Value
|
Min Value
|
Max Value
|
0x2200
|
0x5
|
Unsigned
|
2 Bit
|
Read/Write
|
enabled
|
disabled
|
enabled
|
0
|
0
|
1
|
Supported on Platforms:
i.MX 35
|
i.MX 6 A-Series
|
i.MX 6 B-Series
|
ISOBUS
|
Yes
|
Yes
|
Yes
|
No
|
|
"type of distance units to be used"
similar to ISO 11783-7, A.23.5.2
0: metric [mm, m, km]
1: imperial [in, ft, mls]
Index
|
Subindex
|
Storage Type
|
Length
|
Access Type
|
Remanent
|
Force Writing
|
Initialize as Invalid
|
Default Value
|
Min Value
|
Max Value
|
0x2200
|
0x6
|
Unsigned
|
2 Bit
|
Read/Write
|
enabled
|
disabled
|
enabled
|
0
|
0
|
1
|
Supported on Platforms:
i.MX 35
|
i.MX 6 A-Series
|
i.MX 6 B-Series
|
ISOBUS
|
Yes
|
Yes
|
Yes
|
No
|
|
"type of area units to be used"
similar to ISO 11783-7, A.23.5.3
0: metric [m², ha (hectares)]
1: imperial [sqare feet, acres]
Index
|
Subindex
|
Storage Type
|
Length
|
Access Type
|
Remanent
|
Force Writing
|
Initialize as Invalid
|
Default Value
|
Min Value
|
Max Value
|
0x2200
|
0x7
|
Unsigned
|
2 Bit
|
Read/Write
|
enabled
|
disabled
|
enabled
|
0
|
0
|
1
|
Supported on Platforms:
i.MX 35
|
i.MX 6 A-Series
|
i.MX 6 B-Series
|
ISOBUS
|
Yes
|
Yes
|
Yes
|
No
|
|
"type of volume units to be used"
similar to ISO 11783-7, A.23.5.4
0: metric [mm³, m³, l]
1: imperial [ga (gallon)]
2: US [ga (gallon)]
Index
|
Subindex
|
Storage Type
|
Length
|
Access Type
|
Remanent
|
Force Writing
|
Initialize as Invalid
|
Default Value
|
Min Value
|
Max Value
|
0x2200
|
0x8
|
Unsigned
|
2 Bit
|
Read/Write
|
enabled
|
disabled
|
enabled
|
0
|
0
|
2
|
Supported on Platforms:
i.MX 35
|
i.MX 6 A-Series
|
i.MX 6 B-Series
|
ISOBUS
|
Yes
|
Yes
|
Yes
|
No
|
|
"type of mass units to be used"
similar to ISO 11783-7, A.23.5.5
0: metric [g, kg, t]
1: imperial [long tonnes (UK), pounds]
2: US [short tonnes (US), pounds]
Index
|
Subindex
|
Storage Type
|
Length
|
Access Type
|
Remanent
|
Force Writing
|
Initialize as Invalid
|
Default Value
|
Min Value
|
Max Value
|
0x2200
|
0x9
|
Unsigned
|
2 Bit
|
Read/Write
|
enabled
|
disabled
|
enabled
|
0
|
0
|
2
|
Supported on Platforms:
i.MX 35
|
i.MX 6 A-Series
|
i.MX 6 B-Series
|
ISOBUS
|
Yes
|
Yes
|
Yes
|
No
|
|
"type of temperature units to be used"
similar to ISO 11783-7, A.23.5.6
0: metric [°K, °C]
1: imperial [°F]
Index
|
Subindex
|
Storage Type
|
Length
|
Access Type
|
Remanent
|
Force Writing
|
Initialize as Invalid
|
Default Value
|
Min Value
|
Max Value
|
0x2200
|
0xa
|
Unsigned
|
2 Bit
|
Read/Write
|
enabled
|
disabled
|
enabled
|
0
|
0
|
1
|
Supported on Platforms:
i.MX 35
|
i.MX 6 A-Series
|
i.MX 6 B-Series
|
ISOBUS
|
Yes
|
Yes
|
Yes
|
No
|
|
"type of pressure units to be used"
similar to ISO 11783-7, A.23.5.7
0: metric [hP, kP, P (Pascal)]
1: imperial [PSI]
Index
|
Subindex
|
Storage Type
|
Length
|
Access Type
|
Remanent
|
Force Writing
|
Initialize as Invalid
|
Default Value
|
Min Value
|
Max Value
|
0x2200
|
0xb
|
Unsigned
|
2 Bit
|
Read/Write
|
enabled
|
disabled
|
enabled
|
0
|
0
|
1
|
Supported on Platforms:
i.MX 35
|
i.MX 6 A-Series
|
i.MX 6 B-Series
|
ISOBUS
|
Yes
|
Yes
|
Yes
|
No
|
|
"type of force units to be used"
similar to ISO 11783-7, A.23.5.8
0: metric [kN, N (Newton)]
1: imperial [pounds-force]
Index
|
Subindex
|
Storage Type
|
Length
|
Access Type
|
Remanent
|
Force Writing
|
Initialize as Invalid
|
Default Value
|
Min Value
|
Max Value
|
0x2200
|
0xc
|
Unsigned
|
2 Bit
|
Read/Write
|
enabled
|
disabled
|
enabled
|
0
|
0
|
1
|
Supported on Platforms:
i.MX 35
|
i.MX 6 A-Series
|
i.MX 6 B-Series
|
ISOBUS
|
Yes
|
Yes
|
Yes
|
No
|
|
"general unit system setting"
similar to ISO 11783-7, A.23.5.9
0: metric
1: imperial
2: US
Index
|
Subindex
|
Storage Type
|
Length
|
Access Type
|
Remanent
|
Force Writing
|
Initialize as Invalid
|
Default Value
|
Min Value
|
Max Value
|
0x2200
|
0xd
|
Unsigned
|
2 Bit
|
Read/Write
|
enabled
|
disabled
|
enabled
|
0
|
0
|
2
|
Supported on Platforms:
i.MX 35
|
i.MX 6 A-Series
|
i.MX 6 B-Series
|
ISOBUS
|
Yes
|